The ratio of the focal length of a digital camera lens to a 35mm still camera lens. J Cataract Refract Surg. [334]: data by Dr. Humberto Carreras, Las Palmas, Spain
[69]: data by Dr.H.Strobl, Rosenheim, Germany
[257]: data by Dr. Klaus Mller, Innsbruck, Austria
1stQ Basis Z A=118.0 a0=0.325 a1=0.255 a2=0.141 pACD=5.01 sf=1.25 A=118.1 A=118.3 672 [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350]
[44]: data by E.Hurst, MD, USA
Constants to download: Biometer: all Haag-Streit Lenstar Haag-Streit Lenstar LS900 Heidelberg E. Anterion Nidek AL-Scan Oculus Pentacam Okulix Tomey OA-2000 Topcon Aladdin Zeiss IOLMaster Zeiss IOLMaster 500 Zeiss IOLMaster 700 Ziemer GALILEI G6 [285]: data by Dr. Miguel Angel Perez, Gran Canaria, Spain
[44]: data by E.Hurst, MD, USA
The AcrySof IOL (model SA60AT) is an ultraviolet-absorbing . Domilens Nex-Load Preloaded A=119.2 a0=1.73 a1=0.40 a2=0.10 pACD=5.87 sf=2.11 A=119.5 A=120.0 98 [222]
[307]: data by Prof.Dr.P.Rieck, Berlin, Germany
[120]: data by Dr.L.Tschernjakov, Berlin, Germany
[33]: data by D.Uthoff, MD, Kiel, Germany
[160]: data by Dr.R.Lehmann, Mnchengladbach, Germany
Hanita SEELENS AF A=119.0 a0=1.25 a1=0.40 a2=0.10 pACD=5.42 sf=1.67 A=118.8 A=119.2 27 [136]
[98]: data by A.Rivett, Adelaide, Australia
Eyeol EYE-DIFF Plus A=118.0 a0=0.93 a1=0.40 a2=0.10 pACD=5.15 sf=1.39 A=118.4 A=118.6 75 [243],[371]
IOL constants will differ accordingly. CODE: NS010693039. [316]: data by Prof.Dr.E.Fabian, Rosenheim, Germany
[344]: data by Randy Ennen MD, Fort Smith, AR, USA
1stQ Basis Q A=118.0 a0=0.278 a1=0.427 a2=0.120 pACD=5.02 sf=1.25 A=118.1 A=118.3 601 [253],[272],[245]
[266]: data by Dr. A. Hhn, Oldenburg, Germany
SA60AT : 6.0 : Anterior Asymmetric Biconvex : 13.0 : 0 +6.00 to +30.0 and +31.0 to +40.0 in 1.0 diopter increments . Ophtec PC410 A=117.5 a0=0.89 a1=0.40 a2=0.10 pACD=5.06 sf=1.31 A=118.2 A=118.4 17 [7]
Rayner Centerflex 570 H A=118.0 a0=1.04 a1=0.40 a2=0.10 pACD=5.22 sf=1.45 A=118.4 A=118.7 118 [38],[52]
[119]: data by Prof.Dr.R.Welt, Ludwigshafen, Germany
HHS Vulnerability Disclosure, Help [253]: data by Prof.Dr.M.Bhnke, Hamburg, Germany
[294]: data by Prof. Mark Packer MD, Eugene, OR, USA
Polytech Polylens H35(Y35) (+) A=118.2 a0=0.95 a1=0.40 a2=0.10 pACD=5.12 sf=1.34 A=118.2 A=118.4 41 [200]
ATTENTION: Refer to the Directions for Use labeling for a complete list of indications, warnings and precautions.REFERENCES: https://professional.myalcon.com/cataract-surgery/intraocular-lens/acrysof-iq-monofocal-iol/. ZEISS CT 47LC (Acri.Lyc 47LC) A=117.7 a0=0.308 a1=0.300 a2=0.133 pACD=4.96 sf=1.17 A=117.9 A=118.0 192 [213],[214]
[20]: data by C.Pommerencke, MD, Vejle, Denmark
[237]: data by Dr.Matteo Piovella, Monza, Italy
[393]: data by Dres Becker, Cordero, Maruniak. [228]: data by Dr.R.v.Horenbeeck, Antwerpen, Belgium
[218]: data by Dr.Jens Klett, Herne, Germany
[243]: data by Jorge Buonsanti MD / Mariana Fuentes MD, Buenos Aires, Argentina
[285]: data by Dr. Miguel Angel Perez, Gran Canaria, Spain
ZEISS AT TORBI 709 MP A=118.3 a0=1.13 a1=0.40 a2=0.10 pACD=5.37 sf=1.59 A=118.5 A=118.3 48 [372]